Kalzip have produced a set of downloadable BIM models providing specifiers using the advanced 3D software with a standard range of Kalzip system build ups. This initial family of intelligent objects has been produced using Autodesk’s Revit and is now freely available to download, many with a complementary series of supporting documents including; NBS specifications, a user guide and comprehensive technical details providing construction professionals with a fully supported BIM ready solution.

Over several years Kalzip have established a solid background of experience through working on a number of technically complex projects requiring these advancing modelling techniques and are fully equipped and knowledgeable in the application of all Kalzip products, providing a service supporting bespoke and tailored solutions to meet exacting and specification criteria from the most demanding of individual projects.

Kalzip Acoustic Deck Roof System - High Humidity - U-value 0.18 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Acoustic Deck Roof System - High Humidity - U-value 0.18 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in high humidity environments with an acoustic requirement, such a swimming pools. Suitable for rafter support systems. Supplied in Revit format.

 

Size: 352 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Acoustic Deck Roof System - U-value 0.18 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Acoustic Deck Roof System - U-value 0.18 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with an acoustic requirement, such as sports halls and airports. Suitable for rafter support systems. Supplied in Revit format.

 

Size: 316 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Acoustic Liner Roof System - U-value 0.18 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Acoustic Liner Roof System - U-value 0.18 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with an acoustic requirement, such as sports halls and airports. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 352 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Acoustic Liner-Deck Roof System - Rw value 49dB from Kalzip Ltd CAD Drawing

Kalzip Acoustic Liner-Deck Roof System - Rw value 49dB

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with a high performance noise break in/out requirement, such as cinemas and schools. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 376 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Deck Roof System - U-value 0.20 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Deck Roof System - U-value 0.20 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for general use. Suitable for rafter support systems. Supplied in Revit format.

 

Size: 312 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip FC Facade/Rainscreen System from Kalzip Ltd CAD Drawing

Kalzip FC Facade/Rainscreen System

Cladding (External, General)

 

BIM model of a Kalzip Facade/Rainscreen system for general use. Suitable for all cladding sub-constructions. Supplied in Revit format.

 

Size: 284 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Liner Roof System - U-value 0.15 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Liner Roof System - U-value 0.15 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with a high thermal performance requirement. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 364 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Liner Roof System - U-value 0.25 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Liner Roof System - U-value 0.25 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for general use. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 364 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Low U-value Liner Roof System - U-value 0.09 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Low U-value Liner Roof System - U-value 0.09 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with an extremely high thermal performance requirement. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 316 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Ribbed Liner Roof System - U-value 0.18 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Ribbed Liner Roof System - U-value 0.18 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for use in buildings with a good thermal performance requirement. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 332 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

Kalzip Ribbed Liner Roof System - U-value 0.20 W/m2K from Kalzip Ltd CAD Drawing

Kalzip Ribbed Liner Roof System - U-value 0.20 W/m2K

Roof Decking (Metal)

 

BIM model of a Kalzip roof system for general use. Suitable for rafter and purlin support systems. Supplied in Revit format.

 

Size: 312 KB

Format: Revit (RVT)

Last Updated: 10/08/2012

 

What is BIM?

 

Building Information Modelling (BIM) is the collaborative process of creating a digital, 3D representation of a project containing information on all of its physical and functional characteristics and those of its components, thus forming a reliable basis for decisions during its life-cycle; from initial concept through to demolition.

 

More Information on BIM