Residential, Enfield
21 February 2013 by NanoPore Insulation Ltd
Architect: Energy Conscious Design
Nanopore Insulation Limited’s Vacuum
Insulation Panels have been utilised in this
‘Retrofit for the Future’ project at 13 Joyce
Avenue, London.
The aim of this scheme was to meet the UK
governments target for reducing greenhouse
gas emissions by 80% by 2050, while also
cutting energy use dramatically.
ECD Architects utilised their retrofit experience
to comprehensively address thermal bridging
concerns and fabric air tightness whilst
simultaneously employing advanced insulation
materials to address heat loss.
Fig. 1
The goal of this project was to reduce both the primary energy requirement and CO2
emissions. The property’s annual CO2 emissions were 160 (kgCO2/m2.yr), and this is
forecasted to reduce to 29 (kgCO2/m2.yr). The primary energy requirement was 678
(kWh/m2.yr) and this is forecasted to reduce to 142 (kWh/m2.yr).
One of the major issues for ECD Architects was how to approach the thermal upgrade of the
external fabric of the property. The existing external walls were a combination of cavity wall,
brick solid wall and tile clad solid wall. Utilising traditional forms of insulation would have meant
cladding the property with up to 150mm of PUR insulation.
The approach taken by ECD Architects was for the existing walls to be externally clad with a
combination of 25mm thick Nanopore Vacuum Insulated Panels (VIP’s) and rigid phenolic
board. This system provides a U-value of 0.15w/m2K within only a 65mm depth. The existing
windows were replaced with high performance Passivhaus standard windows with a whole
window U-value of 0.75w/m2K.
The process of installing this VIP based external
wall insulation system began with a matrix of
25mm thick phenolic battens mechanically fixed
back to the outside of the existing façade. This
matrix of phenolic battens was necessary to both
hold the VIP’s in place, and also to provide fixing
points for the secondary layer timber battens
which would support the tile battens and final
render coat.
Nanopore Insulation produced factory premade
panels of varying sizes to suit the phenolic
batten layout which had been determined on site
(Vacuum Insulation Panels cannot be cut on site)
Fig. 2 which were then placed between the battens.
(Fig.2)
The next stage was for the timber battens to be
mechanically fixed back through the underlying
phenolic battens (reduced thermal bridge due to
phenolic battens) and then the secondary
phenolic insulation layer was fitted over the
VIP’s.(Fig. 3 & 4) The phenolic board was
temporarily taped in place. This then allowed the
tile cross battens to be fitted where necessary or
the mesh layer for the final render coat.
The completed system is shown in Fig. 1. Bob
Deane, MD of Wetherby Building Systems says
“this is the second retrofit of VIPs for our
Fig. 3 company and we see much potential for the
future in this area”. The property will be
monitored over a one year period in order to
measure its performance in energy reduction.
All Case Studies from NanoPore Insulation Ltd