21 October 2011 14:06 by H+H UK Limited
Residential, Telford
Architect: Supporta Architecture
Contractor: McPhilips Ltd
Location: Telford
Project description: Rising up to 4 storeys
high, the project is made up of a mix of 1
and 2 bedroom self-contained apartments for
rent with extensive communal areas.
The Rå build method of construction with
solid external walls, cavity separating
walls, and PCC plank separating floors was
the preferred approach, with an insulated
external render. Approximately 110,000
H+H UK aircrete blocks were used in
the build.
To facilitate areas with brick facings, some of
the external elevations are of cavity
construction, with 100mm cavity. 100mm
full fill mineral wool was used. The entire
interior is finished with plasterboard dry
lining on dabs. A stand and seam aluminium
clad roof completes the building.
External render specification:
Repex took just under 10 weeks to
complete their work. The Permarock
insulated render system with 100mm
mineral fibre insulation board was used.
Repex worked to achieve a U value of
between 0.26 & 0.28 Wm2K.
External render contractor comment:
“We found the H+H aircrete solid
wall substrate to be very flat and it
accommodated the render without
any issues whatsoever. As the site
was in a clean condition, we were
able to complete our work quickly
and on time”.
Andy Simmonds
Contracts Manager, Repex LTD
Product used / aircrete specification:
External walls -
Solid 215mm 7.3 and 8.7 N/mm2 H+H
Plus Blocks, face size 610 x 140mm
Separating walls -
Two leaves of 100mm 7.3 and
8.7N/mm2 H+H Jumbo Bloks, face
size 610 x 270mm
Separating floors -
150mm Precast concrete Slabs
Build time
(blockwork and separating floors):
Following on from the work of Chase
Norton, who had built to first floor level,
further construction took 14 working weeks
to completion.
Reason for choosing H+H aircrete products:
Contractor Chase Norton was attracted to
the robust simplicity of a solid external wall.
The use of external insulated render means
all the masonry is inside the envelope
which, together with the use of concrete
separating floors creates a high thermal
mass. The building will be slow to lose its
heat in cold conditions, but will also remain
cooler in the summer months, thus
reducing the need for air conditioning.
This slowing of the heating/cooling cycle
coupled with the building’s performance in
sound control will provide greater comfort
for the occupants as well as reduced energy
consumption. McPhilips won the contract
to complete the job following the collapse
of Chase Norton and were pleased with
how it went.
Acoustics:
The entire development had to comply with
Part E of the current Building Regulations
covering Rooms for Residential Purposes.
The minimum requirements being:
Walls; min 43dB DnT,w+Ctr
Floors; airbourne - min 45dB DnT,w+Ctr
Impact; max 62dB DnT,w+Ctr.
The separating walls - cavity masonry were
constructed to Robust Details E-WM-10.
The entire development had to comply with
Part E of the current Building Regulations
covering Rooms for Residential Purposes.
The minimum requirements being:
Walls;
min 43dB Dntw + Ctr: Floors; airbourne -
min 45dB Dntw + Ctr, Impact; max 62dB
Lntw. The separating walls - cavity masonry
were constructed to Robust Details
E-WM-10 and E- WM-13.
Airtightness:
Thin-Jointed blockwork has an air tightness
of approximately 1m3/hr/m2,which assists in
achieving site test results ranging from
2.88 - 4.26m3/hr/m2.
H+H UK recommended
contractor comment:
“We demonstrated with this project
that the Rå Build method of
construction with the Thin Jointed
aircrete is not just a quick fix to
streamline the construction process,
but also contributes to the thermal
mass of a building.”
Richard Afford
Surveyor, Minett Group
Product/system benefits:
As an environmentally friendly product,
aircrete offers many benefits in
construction that add to the sustainability
credentials of a project and enhance
thermal and sound insulation, thermal
mass and air-tightness.
The chemical reaction that forms aircrete’s
structure results in each block being
made up of millions of non-interconnecting
cells. This structure is key to many of
the Product’s benefits, as it reduces the
passage of heat, sound and moisture
through the building’s envelope.
Performance is further enhanced by the use
of the H+H thin joint system, which reduces
the thickness of the mortar joints from
10mm to 2mm.
Thermal mass:
The higher average temperatures that are
expected from climate change make
summer overheating a potential problem
within the lifetime of the building. One of
the requirements within AD ‘L’ is that the
designer checks for summer overheating,
and thermal mass is recognised as one
means of reducing this effect.
With homes built with H+H aircrete,
the internal temperatures during summer
months is cooler as the aircrete products
absorb heat in the daytime and release
this stored heat at cooler times. Summer
overheating is typically a problem for
light framed systems.
Buildings with higher mass also have a
beneficial effect on the heating pattern in
wintertime. By offering good thermal
insulation, thermal inertia and airtightness
properties, aircrete reduces the extremes
of the internal temperature within the
building, keeping it at a more consistent,
comfortable level and reducing the highs
and lows that would be seen in lighter
structures with minimal thermal inertia.
Client comment:
“This was our first time with aircrete and I would be happy to use it again. The material
enabled us to meet the criteria for using a modern method of construction and comply
with or exceed required building regulations. We also had the confidence that comes
with a familiar type of building process and well established trade practice”.
Tony Hewitt Project Manager, Wrekin Housing Trust
Other benefits include:
Construction programmes are simplified
as the inner shell can be completed
before external cladding by one
contractor
Compliance with Part L and Part E of
the Building Regulations
Lead time kept to a minimum as all
components for Thin-Joint block-work
are available ‘off the shelf’
Block-work is design flexible and
highly adaptable
Thin-Joint block-work rated walls have
an air tightness around 1m3/hr/m2
Approximately 75% less mortar is
needed on site. Celfix takes up less
storage area than traditional mortar
H+H aircrete applications:
Internal and external leaf in cavity walls
Solid walls
Separating / party walls
Flanking walls
Partitions
Multi-storey
Foundations
Submit your news
Send us your construction related news and press releases to feature on specifinder.com free-of-charge. Email them to [email protected]
Add your company
An entry on specifinder.com gives you exposure to over 32,000 unique visitors a month. For further information, please email [email protected]
Tweets by @specifinder